+8615211106309sales@labeks.com

Raman Microscope Imaging Spectrometer with Auto Focus for Material Science

Integrating microscope and Raman spectrometer strengths, the LATR8300 series Raman Microscope Imaging Spectrometer offers visual precise positioning, detecting surface-state Raman signals of samples and displaying them in real time on a computer to streamline micro-area Raman detection.

  • model
    LATR8300 Series
  • brandLABEKS
  • min. order1 pcs
  • packageplywood case package

description

The high-end LATR8300 model supports fully automated operations including auto-focus, auto-scan, one-click execution, batch testing, and uniform scanning, enabling rapid acquisition of highly reliable Raman scan imaging data without prolonged waiting periods;

Equipped with a Raman system-specific objective lens, the LATR8300 produces laser spots that approach the diffraction limit. Focus information is accurately and intuitively displayed on a computer via a 3-megapixel camera, eliminating the issue common in standard Raman systems where the collected signal’s focal plane deviates from the true optimal plane, thus enhancing Raman spectrum quality.

Featuring no moving parts for optical path switching, all optical components of the LATR8300 are assembled in a solid-state configuration, ensuring exceptional operational stability. This design eliminates camera imaging light path loss and enables complete separation of camera imaging and Raman signal acquisition, delivering optimal signal intensity.

Additionally, the LATR8300 integrates a high-performance Raman spectrometer optimized specifically for Raman microscopy systems. Boasting industry-leading sensitivity, signal-to-noise ratio, and stability, it provides robust support for advanced Raman research initiatives.

Applications:

Nanoparticles and Advanced Materials

Research Institute Studies

Life Sciences

Forensic Analysis

Materials Science

Medical Immunoassays

Agricultural and Food Authentication

Water Contamination Analysis

Model

Functional

LATR8300BS

Base

LATR8300AF

Auto Focus

LATR8300MP

Mapping type (auto focus, auto scantype)

LATR8300TW

Two Lasers (auto focus, auto scan,trueconfocal,one-button operate type)

Spectrum showing

acetonitrile-spectra.png

sers-raman-spectra.pngsers-raman-spectra-detected.png

alcohol-spectra-scan-by-raman-microscope.png

Raman Resolution

tylenol-spectra-scan-by-raman-microscope.png

petrol-spectra-resolution.png

Reliability

acetonitrile-reliability.png

acetonitrile-intensity-variation.png

features

1. Ultra-high sensitivity with a signal-to-noise ratio exceeding 6000:1

2. Integrated high-performance spectrometer optimized for Raman analysis

3. Fully automated Raman experimentation with integrated auto-focus and auto-scan capabilities

4. Exceptional operational stability for consistent long-term performance

5. High-quality objective lens producing micron-scale laser spots

6. True focus functionality ensures more accurate Raman imaging results

7. Ultra-high spatial resolution for precise micro-area sample analysis

8. Multiple excitation wavelength options: 532, 633, 785, 830, 1064 nm

9. Rapid positioning mechanism to quickly locate the optimal focus position

10. 3-megapixel camera for clear, accurate visual feedback of sample and focus status

11. Exclusive software-controlled optical path switching for flexible operation

12. Imported optical components deliver reliable, high-performance output

13. Direct USB2.0 interface for seamless, high-speed computer connectivity

specifications

Model

LATR8300

Spectralresolution

3 cm-¹(different models, different spectral ranges, slightly different)

Spectralrange

250-2700,200-3500, 200-4300 cm-¹ (other wavelength ranges can be customized, as low as50 cm -1)

Spectralstability

σ/μ<0.5%(COT 8 hours)

Temperaturestability

Spectralshift ≤ 1 cm-¹(10-40℃)

Signal-to-noiseratio

>6000:1

Detector

Semiconductorcooling 2048*64 pixel back-illuminated infrared enhanced CCD

Detectionwavelength range

200nm-1100nm

Pixel size

14 μm * 14μm

Detectordynamic range

13000:1

Laser centerwavelength

785nm(+/-0.5nm)

Microscopecamera system

3 million or5 million pixel industrial camera

Focusingmethod

ConjugateFocus

Laser power

>550mW(software adjustable)

Laser spotdiameter

>1μm

Laserstability

σ/μ<±0.2%

Laser linewidth

0.08 nm

Communicationmode

USB2.0

X, Y axiselectric control two-dimensional platform

X, Y axiselectric control two-dimensional platform

Moving range

50 X 50 mm

Mobileresolution

0.1μm

positioningaccuracy

1μm

Scan speed

20mm/s

Z axis (autofocus)

Z axis (autofocus)

Focusaccuracy

≤ ±0.2 μm

Maximumstroke

20 mm

Focus speed

No more than10 s

why choose us

  • Premium Quality with CE & ISO

    We conduct 100% performance testing on every unit, ensuring its stable operation and superior performance in your application.

  • 24/7 Expert Technical Support

    Our senior engineers are on standby 24/7, ready to provide expert solutions at any time to minimize your operational downtime.

  • 20+ Years R&D & Production

    Our deep technical expertise is your solid guarantee for professional and reliable OEM/ODM services.

  • Trusted in 80+ Countries

    Industry leaders and research institutions in over 80 countries and regions rely on our equipment for stable operation.

  • True Manufacturer, Factory-Direct Price

    Bypass the middlemen to get our factory pricing and speak directly with our core engineers.

  • Rapid & Reliable Delivery

    Our extensive in-stock inventory provides a solid guarantee for rapid and reliable global delivery.

Our Factory

Our factory is powered by a professional and dedicated team. Their commitment to a serious and responsible approach ensures the consistency and reliability of every instrument we build. Our R&D team is composed of experienced engineers specializing in design, technology, and process control.
Our R&D team is composed of experienced engineers specializing in design, technology, and process control. Our strict Quality Control System governs the entire process—from initial design and testing to final production and inspection.

20 Years

Laboratory Solution

58 Experts

In Research & Design

20000 m²

Industrial Plant

7X24 Hours

Expert Support
labeks-laboratory-equipment-production-facility

Request Quotation