Raman Microscope Imaging Spectrometer with Auto Focus for Material Science
Integrating microscope and Raman spectrometer strengths, the LATR8300 series Raman Microscope Imaging Spectrometer offers visual precise positioning, detecting surface-state Raman signals of samples and displaying them in real time on a computer to streamline micro-area Raman detection.
- modelLATR8300 Series
- brandLABEKS
- min. order1 pcs
- packageplywood case package
description
The high-end LATR8300 model supports fully automated operations including auto-focus, auto-scan, one-click execution, batch testing, and uniform scanning, enabling rapid acquisition of highly reliable Raman scan imaging data without prolonged waiting periods;
Equipped with a Raman system-specific objective lens, the LATR8300 produces laser spots that approach the diffraction limit. Focus information is accurately and intuitively displayed on a computer via a 3-megapixel camera, eliminating the issue common in standard Raman systems where the collected signal’s focal plane deviates from the true optimal plane, thus enhancing Raman spectrum quality.
Featuring no moving parts for optical path switching, all optical components of the LATR8300 are assembled in a solid-state configuration, ensuring exceptional operational stability. This design eliminates camera imaging light path loss and enables complete separation of camera imaging and Raman signal acquisition, delivering optimal signal intensity.
Additionally, the LATR8300 integrates a high-performance Raman spectrometer optimized specifically for Raman microscopy systems. Boasting industry-leading sensitivity, signal-to-noise ratio, and stability, it provides robust support for advanced Raman research initiatives.
Applications:
Nanoparticles and Advanced Materials
Research Institute Studies
Life Sciences
Forensic Analysis
Materials Science
Medical Immunoassays
Agricultural and Food Authentication
Water Contamination Analysis
Model | Functional |
|---|---|
LATR8300BS | Base |
LATR8300AF | Auto Focus |
LATR8300MP | Mapping type (auto focus, auto scantype) |
LATR8300TW | Two Lasers (auto focus, auto scan,trueconfocal,one-button operate type) |
Spectrum showing




Raman Resolution


Reliability


features
1. Ultra-high sensitivity with a signal-to-noise ratio exceeding 6000:1
2. Integrated high-performance spectrometer optimized for Raman analysis
3. Fully automated Raman experimentation with integrated auto-focus and auto-scan capabilities
4. Exceptional operational stability for consistent long-term performance
5. High-quality objective lens producing micron-scale laser spots
6. True focus functionality ensures more accurate Raman imaging results
7. Ultra-high spatial resolution for precise micro-area sample analysis
8. Multiple excitation wavelength options: 532, 633, 785, 830, 1064 nm
9. Rapid positioning mechanism to quickly locate the optimal focus position
10. 3-megapixel camera for clear, accurate visual feedback of sample and focus status
11. Exclusive software-controlled optical path switching for flexible operation
12. Imported optical components deliver reliable, high-performance output
13. Direct USB2.0 interface for seamless, high-speed computer connectivity
specifications
Model | LATR8300 |
|---|---|
Spectralresolution | 3 cm-¹(different models, different spectral ranges, slightly different) |
Spectralrange | 250-2700,200-3500, 200-4300 cm-¹ (other wavelength ranges can be customized, as low as50 cm -1) |
Spectralstability | σ/μ<0.5%(COT 8 hours) |
Temperaturestability | Spectralshift ≤ 1 cm-¹(10-40℃) |
Signal-to-noiseratio | >6000:1 |
Detector | Semiconductorcooling 2048*64 pixel back-illuminated infrared enhanced CCD |
Detectionwavelength range | 200nm-1100nm |
Pixel size | 14 μm * 14μm |
Detectordynamic range | 13000:1 |
Laser centerwavelength | 785nm(+/-0.5nm) |
Microscopecamera system | 3 million or5 million pixel industrial camera |
Focusingmethod | ConjugateFocus |
Laser power | >550mW(software adjustable) |
Laser spotdiameter | >1μm |
Laserstability | σ/μ<±0.2% |
Laser linewidth | 0.08 nm |
Communicationmode | USB2.0 |
X, Y axiselectric control two-dimensional platform | X, Y axiselectric control two-dimensional platform |
Moving range | 50 X 50 mm |
Mobileresolution | 0.1μm |
positioningaccuracy | 1μm |
Scan speed | 20mm/s |
Z axis (autofocus) | Z axis (autofocus) |
Focusaccuracy | ≤ ±0.2 μm |
Maximumstroke | 20 mm |
Focus speed | No more than10 s |
why choose us
Premium Quality with CE & ISO
We conduct 100% performance testing on every unit, ensuring its stable operation and superior performance in your application.
24/7 Expert Technical Support
Our senior engineers are on standby 24/7, ready to provide expert solutions at any time to minimize your operational downtime.
20+ Years R&D & Production
Our deep technical expertise is your solid guarantee for professional and reliable OEM/ODM services.
Trusted in 80+ Countries
Industry leaders and research institutions in over 80 countries and regions rely on our equipment for stable operation.
True Manufacturer, Factory-Direct Price
Bypass the middlemen to get our factory pricing and speak directly with our core engineers.
Rapid & Reliable Delivery
Our extensive in-stock inventory provides a solid guarantee for rapid and reliable global delivery.

Our Factory
20 Years
58 Experts
20000 m²
7X24 Hours












