LMN-S Series Laboratory Water Purification Machine: 18.25 MΩ·cm Output for Biochemical & Analytical Applications
Delivering 18.25 MΩ·cm @25℃ ultra-pure water with ultra-low contaminants, ions and organics, this laboratory water purification machine supports biochemical analyzers, general chemistry, biological histology, microbiological analysis, HPLC, photographic film washing, and microbiological culture medium preparation.
- modelLMN-S Series
- brandLABEKS
- min. order1 pcs
- packageplywood case package
description
Engineered to generate ultra-pure water for diverse industrial and laboratory applications, the LMN-S Series Laboratory Water Purification Machine is a high-performance purification system. Leveraging advanced filtration and purification technologies, it ensures exceptional water purity by reducing contaminants, ions, and organic substances to extremely low levels.
features
Backlit LCD display with dual-water real-time monitoring: simultaneously shows RO conductivity values, UP resistivity values, and system operating status indicators. Menu-based operation allows modification and setting of multiple measurement parameters, with real-time status prompts for high-pressure shutdown, low-pressure alarm, and full-water shutdown.
Dual-wavelength UV germicidal lamp for effective sterilization and TOC reduction; original imported 5000D ultrafilter module for efficient endotoxin and pyrogen removal (optional).
Comprehensive system management capabilities for deionized water production, ultra-pure water generation, water intake, and system circulation.
Complete protection and fault alarm system, including low-water protection, high-pressure full-water protection, and universal fault alerts.
RO and ultra-pure water quality over-limit alarm, automatic filter element replacement reminders, and customizable water intake timing; one-touch water dispensing with automatic RO/UP water intake indicator prompts.
Dual password protection: supports both user-specific password access and factory-mode initial password protection.
Programmable standby and auto-shutdown functionality: all outputs stop automatically when the set shutdown time is reached, and the system enters shutdown mode.
Full lifecycle management for historical alarms, water intake records, and consumable lifespan; a USB port is provided to export historical alarm and water intake data.
Chassis adopts a spray-plating finish and side-door opening design. The filtration system uses 11″ U-type Korean quick-connect filter columns for easy replacement and maintenance, with support for water quality and output capacity upgrades.
Equipped with a portable test pen for on-demand testing of TDS content, conductivity, and water temperature.
Ultra-low radiation emission, enabled by advanced electromagnetic compatibility design.
specifications
Model | LMN-S | LMN-SF | LMN-SV | LMN-SVF |
|---|---|---|---|---|
Type | Standard | Low Endotoxin | Low TOC | Comprehensive |
Water making speed | 10L/H,20L/H,30L/H | |||
Water requirements | Urbantap water, inlet water pressure: 0.15-0.5mpa, water temperature 5-40℃ | |||
RO waterParameter | ||||
Ion rejection rate | 97%-99% | |||
Organic matter rejection rate | >99% whenMW>200 Dalton | |||
Particle and bacterial rejection | >99% | |||
Application | Front system of ultra-pure water machine, bufferconfiguration, photosensitive film washing, water supply for stabilityexperiment box, meteorological experiment equipment, hydrogen generator,battery adding liquid, electroplating and other instruments | |||
UP waterParameter(ASTM TYPE I grade water) | ||||
Resistivity | 18.25 M Ω. cm @ 25 ℃ | |||
Heavy metal ion | <0.01 ppb | |||
Total organic carbon (TOC) * | <10ppb | <3ppb | ||
Bacteria | <1 cfu/ml *(with terminal filter) | |||
Particulate matter | <1/ml | |||
Pyrogen | N/A | <0.001 Eu/ml | N/A | <0.001 Eu/ml |
Ribonuclease | N/A | <1pg/ml | N/A | <1pg/ml |
Deoxyribonucleases | N/A | <5pg/ml | N/A | <5pg/ml |
Application | Allkinds of physical and chemical testing, biochemical analysis, bloodexamination, microanalysis, flushing special, HPLC, IC, GC, analysisexperiment | PCR,PPT level analysis, isotope analysis, molecular biology, life science, CDC,drug control institute, quality inspection institute | Atomicabsorption/emission spectrometry, mass spectrometry, TOC detection, Highsensitivity ICP/MS, environmental monitoring, biochip development, traceorganic matter analysis | Molecularbiology, Life sciences, gene research, cell culture, amino acid analysis,protein purification, toxicology, drug development, medical testing |
System configuration | Mainmachine (including 1 set of purification column)+12 L external pressure waterstorage tank +TDS pen + accessory kit | |||
Electrical requirements | 100-240V,50/60Hz, 48-72W | |||
Dimensions | 312×475×475mm | |||
Weight | 30Kg | |||
why choose us
Premium Quality with CE & ISO
We conduct 100% performance testing on every unit, ensuring its stable operation and superior performance in your application.
24/7 Expert Technical Support
Our senior engineers are on standby 24/7, ready to provide expert solutions at any time to minimize your operational downtime.
20+ Years R&D & Production
Our deep technical expertise is your solid guarantee for professional and reliable OEM/ODM services.
Trusted in 80+ Countries
Industry leaders and research institutions in over 80 countries and regions rely on our equipment for stable operation.
True Manufacturer, Factory-Direct Price
Bypass the middlemen to get our factory pricing and speak directly with our core engineers.
Rapid & Reliable Delivery
Our extensive in-stock inventory provides a solid guarantee for rapid and reliable global delivery.

Our Factory
20 Years
58 Experts
20000 m²
7X24 Hours