+8615211106309sales@labeks.com

GC112N Gas Chromatograph: Bidirectional Control for Multi-Industry Analytical Testing

Ideal for precise separation and quantitative analysis, the gas chromatograph serves as a critical tool across petrochemicals, environmental protection, food safety, pharmaceuticals, defense, forensic inspection, and ultra-pure material sectors.

  • model
    GC112N
  • brandLABEKS
  • min. order1 pcs
  • packageplywood case package

description

The GC112N integrates PC-side reverse control software and a built-in chromatography workstation, enabling synchronous bidirectional control via both PC reverse operation and the host’s touch screen. It features a dedicated mounting interface for autosamplers, compatible with models of various specifications. A multi-core, 32-bit embedded hardware platform guarantees stable, uninterrupted instrument operation. Equipped with a logarithmic amplifier, the device produces detection signals without a cutoff value and delivers well-defined peak shapes; its expandable synchronous external trigger function also allows simultaneous activation of the host and workstation via external signals such as autosamplers or thermal analyzers.

features

1. Integrates standard PC control software and a built-in chromatographic workstation to enable PC-side reverse control and synchronous bidirectional operation via the host touch screen.

2. A multi-core, 32-bit embedded hardware system ensures consistent, reliable instrument operation.

3. Boasts comprehensive system self-check functionality and automatic fault identification capabilities.

4. Comes with 8 external event expansion interfaces, compatible with various functional control valves that operate according to user-defined time sequences.

5. Includes RS232 communication port, LAN network port, and a dedicated data acquisition card.

6. Features an autosampler installation and positioning interface, compatible with autosamplers of diverse specifications.

7. Utilizes a logarithmic amplifier for detection signals with no cutoff value and excellent peak shapes; the expandable synchronous external trigger function enables simultaneous startup of the host and workstation via external signals (e.g., autosamplers, thermal analyzers).

8. Offers one-button startup functionality and can store up to 20 groups of sample test modes.

9. Provides gas shortage alarm protection and heating control safeguards: the column oven fan motor and heating system shut down automatically when the oven door is opened.

10. Supports automatic split flow/split ratio control to reduce carrier gas consumption.

11. Equipped with a 7-inch color touch screen for digital display of carrier/hydrogen/air channel flow (pressure) data.

specifications

Model

GC112N

Oven

Contentproduct: 22L

Temperaturecontrol range: 5℃~ 400℃at room temperature

Temperaturecontrol accuracy:±0.1℃

Heatingrate: 0.1 ~ 60℃/ min

Programtemperature rise order: 9

Programheating repeatability:≤2%

Cooling way:open the door after

Coolingspeed:≤10mins (250℃~ 50℃)

Controlsoftware function

Columntemperature box control

Detectorcontrol

Injectorcontrol

Map display

SamplerInjector

Temperaturecontrol range: 7℃~ 420℃at room temperature

Temperaturecontrol method: independent temperature control

Carrier gasflow control mode: constant pressure

Number ofsimultaneous installations: 3 at most

Type ofinjection unit: filling column, shunt

Split ratio:split ratio display

Cylinderpressure range: 0 ~ 400kPa

Cylinderpressure control accuracy: 0.1kPa

Flow settingrange: H2 0 ~ 200ml / minN2 0 ~150ml / min

Detector

FID, TCD(optional)

Temperaturecontrol: Max. 420℃

Number ofsimultaneous installations: 2 at most

Ignitionfunction: automatic

Hydrogenflame ionization detector (FID)

Detectionlimit:≤3×10-12g/s (n-hexadecane)

Baselinenoise:≤5×10-14A

Baselinedrift:≤6×10-13A

Dynamic range:107

RSD: 3% orless

Supplyvoltage: AC220V±22V,50Hz±0.5Hz

Power: 3000W

Optional

Thermalconductivity detector (TCD)

Sensitivity:5000mV•mL/mg(n-cetane)

Baselinenoise:≤0.05 mV

Baselinedrift:≤0.15mV / 30min

Dynamic range:105

Packedcolumn

Capillarycolumn

why choose us

  • Premium Quality with CE & ISO

    We conduct 100% performance testing on every unit, ensuring its stable operation and superior performance in your application.

  • 24/7 Expert Technical Support

    Our senior engineers are on standby 24/7, ready to provide expert solutions at any time to minimize your operational downtime.

  • 20+ Years R&D & Production

    Our deep technical expertise is your solid guarantee for professional and reliable OEM/ODM services.

  • Trusted in 80+ Countries

    Industry leaders and research institutions in over 80 countries and regions rely on our equipment for stable operation.

  • True Manufacturer, Factory-Direct Price

    Bypass the middlemen to get our factory pricing and speak directly with our core engineers.

  • Rapid & Reliable Delivery

    Our extensive in-stock inventory provides a solid guarantee for rapid and reliable global delivery.

Our Factory

Our factory is powered by a professional and dedicated team. Their commitment to a serious and responsible approach ensures the consistency and reliability of every instrument we build. Our R&D team is composed of experienced engineers specializing in design, technology, and process control.
Our R&D team is composed of experienced engineers specializing in design, technology, and process control. Our strict Quality Control System governs the entire process—from initial design and testing to final production and inspection.

20 Years

Laboratory Solution

58 Experts

In Research & Design

20000 m²

Industrial Plant

7X24 Hours

Expert Support
labeks-laboratory-equipment-production-facility

Request Quotation