+8615211106309sales@labeks.com

LUD-8 Double Beam UV VIS Spectrophotometer: 190-1100nm Range for Multi-Field Lab Applications

Engineered for accurate photometric, quantitative and qualitative analysis, this UV VIS Spectrophotometer meets the demands of health & epidemic prevention, academic teaching & research, environmental monitoring, agriculture, forestry, manufacturing, municipal authorities, scientific institutions, water conservancy surveying and petrochemical sectors.

  • model
    LUD-8
  • brandLABEKS
  • min. order1 pcs
  • packageplywood case package

description

1. Photometric Measurement: Within the 190-1100nm range, users can select a custom single-point test wavelength and corresponding method to measure sample absorbance or transmittance. Direct sample concentration reading is enabled by inputting standard concentration values or concentration factors.

2. Quantitative Measurement: Determine the concentration of unknown sample solutions using pre-established calibration curves with known parameters, or automatically generate standard solution curves. It supports first-order zero-crossing, second-order, and third-order curve fitting, with optional single-wavelength calibration, dual-wavelength calibration, and three-point calibration methods. All standard curves are storable and retrievable.

3. Qualitative Measurements: Define a wavelength range and scan interval to perform interval-based absorbance, transmittance, reflectance, and energy measurements on solid or liquid samples. Additional spectrum processing functions include overlay, zoom, smoothing, filtering, peak/valley detection, saving, and printing.

4. Time-Based Measurement (Kinetic Measurement): At a set wavelength, the instrument scans samples at specified time intervals to record absorbance or transmittance changes. By inputting a concentration factor, absorbance values can be converted to concentration or reaction rate, supporting enzyme kinetic reaction rate calculations. Measured spectra can be processed via overlay, scaling, smoothing, filtering, peak/valley detection, and derivation.

5. DNA/Protein Measurement: Targeted absorbance measurements at 260nm/280nm/230nm/320nm enable calculation of DNA and protein concentrations and ratio values per built-in formulas.

6. Multi-Wavelength Measurement: Users can set multiple wavelength points (N wavelengths) to measure absorbance or transmittance of sample solutions, with the ability to test single-wavelength absorbance and transmittance values individually.

7. Instrument Calibration Measurement: Built-in calibration functions include wavelength maximum allowable error verification, transmittance maximum allowable error testing, and stray light measurement.

8. Auxiliary Functions: Track accumulated deuterium lamp and tungsten lamp runtime; independently control deuterium and tungsten lamp on/off status; select UV/visible light switching wavelength; choose operating language (Chinese, English); enable automatic wavelength calibration; and use Bluetooth connectivity.

9. Optional PC Reverse Control Software Package: Adds extended functions including quantitative measurement, qualitative measurement, time-based measurement, DNA/protein measurement, multi-wavelength measurement, 3D graphic analysis, and spectrum overlay analysis.

features

1. Critical components including deuterium lamps, tungsten lamps, photocells, and precision lead screws are sourced from reputable international brands, ensuring consistent, high-reliability instrument performance.

2. High-resolution C-T configuration monochromator provides excellent stability, reproducibility, and measurement accuracy.

3. Integrated aviation-grade aluminum alloy substrate and precision-machined mirror mount ensure long-term optical path stability.

4. Advanced ARM microcomputer technology, optimized electronic circuits, and high-performance signal processing deliver stable, reliable data. Additional features include USB disk data storage/export, one-click software upgrade, and Bluetooth printing for flexible data output.

5. 7-inch color touchscreen LCD with a navigational menu interface offers clear operation commands and built-in error-prevention functions. Intuitive touchscreen + dual-button operation mode allows for glove-compatible use, even without prior manual review.

6. Rigorous manufacturing processes and 32 key quality control points ensure exceptional instrument durability and longevity.

7. Large-capacity internal memory supports storage of massive volumes of test data.

8. Four-slot 10-50mm universally adjustable manual sample holder enables convenient testing of cuvettes in various specifications.

9. Independently designed replacement window for deuterium and tungsten lamps features a flange-type positioning structure for quick, easy lamp replacement.

specifications

Model

LUD-8

Opticalsystem

double beam; 1200/mm imported holographic grating

Wavelengthrange

190-1100 nm

SpectralBandwidth

1.8 nm

Maximumallowable error of wavelength

±0.5 nm

Wavelengthrepeatability

≤0.1 nm

Maximumallowable error of transmittance (%T)

±0.3%T; ±0.002Abs(0-0.5Abs); ±0.004Abs (0.5-1.0Abs)

Transmittancerepeatability (%T)

±0.1%T;±0.001Abs (0-0.5Abs); ±0.002Abs (0.5-1.0Abs)

%0 line and100% line noise (%T)

0% line0.2/100% line 0.3

Drift

≤0.2 %T

Baselineflatness

≤0.001 Abs

Stray light(%T)

≤0.03 @220nmand 360nm

Supplyvoltage adaptability

≤0.2%T

Photometricrange

0-200%T,-0.301-3A, 0-9999C(0-9999F)

Test Modes

Transmission,Reflection, Absorbance, Concentration, Energy

Light source

deuteriumlamp + tungsten lamp

Display

7 inch touchscreen display (resolution 800*480)

Systemlanguage

Chinese,English, Russian, Spanish

Softwareupgrade

support Udisk one-key upgrade

Data output

U disk,Bluetooth, USB software upload

Data outputformat

CSV

OperationMode

Touch Screen

SampleHolder

Four-slot10-50mm Universal Adjustable Manual Sample Holder

Hostfunction

basic+quantitative+qualitative+time+DNA+multi-wavelength

Printer

Optional,support Bluetooth printing

Power supplyrange

AC90~250V/ 50~60Hz

Dimensions(L×W×H)

470×330×210mm

Weight

12kg

why choose us

  • Premium Quality with CE & ISO

    We conduct 100% performance testing on every unit, ensuring its stable operation and superior performance in your application.

  • 24/7 Expert Technical Support

    Our senior engineers are on standby 24/7, ready to provide expert solutions at any time to minimize your operational downtime.

  • 20+ Years R&D & Production

    Our deep technical expertise is your solid guarantee for professional and reliable OEM/ODM services.

  • Trusted in 80+ Countries

    Industry leaders and research institutions in over 80 countries and regions rely on our equipment for stable operation.

  • True Manufacturer, Factory-Direct Price

    Bypass the middlemen to get our factory pricing and speak directly with our core engineers.

  • Rapid & Reliable Delivery

    Our extensive in-stock inventory provides a solid guarantee for rapid and reliable global delivery.

Our Factory

Our factory is powered by a professional and dedicated team. Their commitment to a serious and responsible approach ensures the consistency and reliability of every instrument we build. Our R&D team is composed of experienced engineers specializing in design, technology, and process control.
Our R&D team is composed of experienced engineers specializing in design, technology, and process control. Our strict Quality Control System governs the entire process—from initial design and testing to final production and inspection.

20 Years

Laboratory Solution

58 Experts

In Research & Design

20000 m²

Industrial Plant

7X24 Hours

Expert Support
labeks-laboratory-equipment-production-facility