10L Heating Cooling Circulator with PLC Control for Reactor Temperature Management
Engineered for precise reactor temperature management, this heating cooling circulator boasts a 10L capacity, intuitive touchscreen interface, integrated heating/cooling capabilities, and customizable temperature ranges including -20℃~200℃ and -40℃~200℃.
- modelLGD-10SZ Series
- brandLABEKS
- min. order1 pcs
- packageplywood case package
description
Model: LGD-10SZ Series
Refrigeration is achieved via a fully hermetic compressor-based mechanical system, integrated with a plate heat exchanger, expansion valve, and pressure protector to meet rigorous cooling demands. For heating, an electric heating element warms the circulating medium efficiently.
A built-in circulation pump and external piping deliver refrigerant or heating medium to the jacket of paired equipment, enabling indirect temperature control of reactor contents. For external circulation, connect the unit’s upper outlet to the reactor’s lower inlet; the medium returns from the reactor’s upper port to the unit’s lower return inlet to form a closed loop.
Rapid switching between heating and cooling modes is supported, with a single compatible medium (high- and low-temperature silicone oil) used for both functions. Eliminating the need for medium changes, this unit replaces separate heating and cooling instruments to streamline operations.
The entire liquid circulation loop is fully sealed and includes an insulated expansion tank. Mechanically connected but not part of active circulation, the tank maintains internal medium temperature below 60°C regardless of system operating temperature, preventing water vapor absorption at low temperatures and oil mist emission at high temperatures.
features
• Premium fully hermetic compressors sourced from France and Denmark ensure reliable, long-lasting performance.
• Integrated PLC module enables PC connectivity for remote operation, supporting multi-point continuous temperature control, segmented programming, constant temperature maintenance, and centralized control of multiple units—streamlining workflows to boost operational efficiency.
• Standard temperature control accuracy reaches ±1°C; connection of an external sensor enhances precision to ±0.5°C.
• Built-in USB port supports data download, allowing users to save and archive temperature and process data for testing, reaction tracking, and compliance documentation purposes.
• Over-temperature protection: the unit automatically powers off when exceeding the set maximum temperature threshold, preventing equipment damage from overheating.
• Power supply safeguards include phase loss, phase sequence error, and over/under voltage protection, with error code E-01 displayed for any of these faults.
• Compressor overheat protection triggers automatic shutdown once the unit’s temperature threshold is exceeded, with error code E-02 displayed.
• Water-cooled models feature water flow and low water pressure protection, with error code E-03 activated for related anomalies.
• Sensor fault protection is included, with error code E-04 displayed to indicate issues.
Installation & Operational Notes:
• Reactor connection pipelines should not exceed a total length of 4 meters (2 meters for supply, 2 meters for return). Exceeding this length risks damage to the reactor’s glass components.
• Temperature ramp-up and ramp-down rates are influenced by ambient conditions, with optimal performance achieved when the environment stays below 30°C.
• For installations in high-humidity environments (humidity >50%), an explosion-proof model is required to ensure safe operation.
• All reactor oil circuit connections must follow the “low inlet, high outlet” configuration to ensure proper medium flow.
specifications
Model | LGD-10/40SZ | LGD-10/80SZ | |
|---|---|---|---|
Operatingtemperature range | -40℃~200℃ | -80℃~200℃ | |
Ambienttemperature | 5℃~35℃ | ||
Environmenthumidity | ≤70% ventilation | ||
Power supply | 220V/50HZ | 380V/50HZ | |
Safetyprotection | Delay, overcurrent, over heat, over temperature, phase sequence, phase loss protection | ||
Displayscreen | 7-inch touchcolor screen program temperature control | ||
Temperaturecontrol accuracy | ±1℃ | ||
Sensor | PT100 | ||
Total powerof the whole machine | 5305W | 7510W | |
Heatingpower | 3000W | ||
Compressor | Specification | Fullyenclosed | |
Quantity | 1 | 2 | |
Power | 2205W | 4410W | |
Coolingcapacity | 6972W | 13944W | |
Therefrigerant | R22 | ||
Bodymaterial | Cold plate sprayedanti-corrosion material | ||
Size(L*W*H) | 695*720*1100mm | ||
Net weight | 86kg | 96kg | |
why choose us
Premium Quality with CE & ISO
We conduct 100% performance testing on every unit, ensuring its stable operation and superior performance in your application.
24/7 Expert Technical Support
Our senior engineers are on standby 24/7, ready to provide expert solutions at any time to minimize your operational downtime.
20+ Years R&D & Production
Our deep technical expertise is your solid guarantee for professional and reliable OEM/ODM services.
Trusted in 80+ Countries
Industry leaders and research institutions in over 80 countries and regions rely on our equipment for stable operation.
True Manufacturer, Factory-Direct Price
Bypass the middlemen to get our factory pricing and speak directly with our core engineers.
Rapid & Reliable Delivery
Our extensive in-stock inventory provides a solid guarantee for rapid and reliable global delivery.

Our Factory
20 Years
58 Experts
20000 m²
7X24 Hours