+8615211106309sales@labeks.com

100L Explosion-Proof Heating Cooling Circulators with ±0.1℃ Accuracy & PLC Remote Control

Designed for pharmaceutical, chemical, and laboratory settings, explosion-proof heating cooling circulators combine heating, cooling, circulation, and control systems, with customizable temperature ranges (-20℃~200℃, -40℃~200℃) to deliver safe, precise temperature control for reactor operations efficiently.

  • model
    LGD-100EX
  • brandLABEKS
  • min. order1 pcs
  • packageplywood case package

description

Refrigeration is achieved via a hermetically sealed compressor-based mechanical system, integrated with plate heat exchangers, expansion valves, and pressure protectors to meet required cooling demands. For heating, electric heating tubes warm the circulating fluid, which is then delivered through external circulation pipes (powered by a built-in circulation pump) to the jacket of supporting equipment, enabling indirect temperature regulation of materials inside reactors.

During external circulation operations, connect the product’s upper outlet pipe to the reactor’s lower inlet pipe. The circulating fluid will then return from the reactor’s upper circulation port via piping to the product’s lower return port, establishing a closed, complete circulation loop.

Explosion-proof high and low temperature circulators support rapid switching between heating and cooling modes. A single medium—high and low temperature silicone oil—serves both functions, eliminating the need for medium replacement after system connection.

The entire liquid circulation system is fully sealed and equipped with an expansion vessel. Thermally insulated from the circulation loop, the expansion vessel is only mechanically connected and does not participate in fluid circulation. Regardless of the circulation loop’s temperature, the medium inside the expansion vessel remains below 60°C, preventing water vapor absorption at low temperatures and oil mist generation at high temperatures.

features

9. All compressors are imported units sourced from France and Denmark, ensuring reliable, long-lasting refrigeration performance.

1. Standard temperature control accuracy is ±1°C; connecting an external sensor enhances this to a temperature difference accuracy of ±0.5°C for more precise regulation.

2. Equipped with a PLC computer module, the system supports remote control via computer, enabling multi-point continuous temperature control, segmented temperature control, and constant temperature operation. A single computer can manage multiple circulators, significantly improving operational convenience and efficiency.

3. A built-in USB interface enables data download functionality, allowing users to save and store data from tests or reactions for future reference and compliance purposes.

4. Over-temperature protection shuts down the equipment automatically if the maximum temperature limit is exceeded, preventing device damage from excessive heat.

5. Comprehensive power supply protection includes safeguards against phase loss, incorrect live wire connection, and over/under voltage conditions, which triggers error code E-01.

6. Compressor overheating protection activates when the compressor reaches its temperature tolerance limit, halting operation and displaying error code E-02.

7. Water-cooled models feature water flow and low water pressure protection, with error code E-03 displayed when anomalies are detected.

8. Sensor fault protection triggers error code E-04 in the event of sensor malfunctions, ensuring prompt detection of issues.

Note:

(1) When connecting the circulator to reactor oil pipes, the total length of supply and return pipes should not exceed 4 meters (2 meters each). Exceeding this length risks damage to the reactor’s glass body.

(2) The temperature ramp-up and ramp-down rates of the circulator are influenced by ambient conditions, with optimal performance achieved at ambient temperatures ≤30°C.

(3) In high-humidity southern regions (humidity>50%), the explosion-proof model is mandatory for safe operation.

(4) Both the circulator and reactor must follow the “low inlet, high outlet” principle for oil circuit connections to ensure proper circulation.

specifications

Model

LGD-100/20EX

LGD-100/40EX

LGD-100/80EX

Matched reactor

80L-100L

80L-100L

80L-100L

Tank Volume(L)

30

30

30

Heating volume(L)

3

3

3

Heating tank size(mm)

¢90×480

¢90×480

¢90×480

Oil tank size(mm)

450*150*450

450*150*450

450*150*450

Working temperature range(℃)

-20℃to +200℃

-40 to +200℃

-80℃to 200℃

Ambient temperature(℃)

≤25

≤25

≤25

Lowest temperature (No load)

-22℃

-42℃

-82℃

Power

380V±10% 50HZ

380V±10% 50HZ

380V±10% 50HZ

Heating power(W)

9000

9000

9000

Cooling power(W)

11240-2100

10280-2565

105700-3270

Temperature accuracy(℃)

±0.1

±0.1

±0.1

Sensor

PT100

PT100

PT100

Medium quality degree

500C.S.T

500C.S.T

500C.S.T

Circulating pump power(w)

250

750

750

Lift head(m)

15

25

25

Flow(L/min)

30

35

35

The compressoradopts explosion-proof treatment (explosion-proof control box,explosion-proof circulating pump, explosion-proof fan, explosion-proof tube)explosion-proof grade ExdIIBT4

why choose us

  • Premium Quality with CE & ISO

    We conduct 100% performance testing on every unit, ensuring its stable operation and superior performance in your application.

  • 24/7 Expert Technical Support

    Our senior engineers are on standby 24/7, ready to provide expert solutions at any time to minimize your operational downtime.

  • 20+ Years R&D & Production

    Our deep technical expertise is your solid guarantee for professional and reliable OEM/ODM services.

  • Trusted in 80+ Countries

    Industry leaders and research institutions in over 80 countries and regions rely on our equipment for stable operation.

  • True Manufacturer, Factory-Direct Price

    Bypass the middlemen to get our factory pricing and speak directly with our core engineers.

  • Rapid & Reliable Delivery

    Our extensive in-stock inventory provides a solid guarantee for rapid and reliable global delivery.

Our Factory

Our factory is powered by a professional and dedicated team. Their commitment to a serious and responsible approach ensures the consistency and reliability of every instrument we build. Our R&D team is composed of experienced engineers specializing in design, technology, and process control.
Our R&D team is composed of experienced engineers specializing in design, technology, and process control. Our strict Quality Control System governs the entire process—from initial design and testing to final production and inspection.

20 Years

Laboratory Solution

58 Experts

In Research & Design

20000 m²

Industrial Plant

7X24 Hours

Expert Support
labeks-laboratory-equipment-production-facility

Request Quotation